Brand Name : MELAN

Model Number : MLF

Place of Origin : China

MOQ : 1pc

Price : Negotiation

Payment Terms : T/T

Supply Ability : 500pcs per month

Delivery Time : 7-10 working days

Packaging Details : In Carton or Wooden Box

Product Name : Electromagnetic Flow Meter

Pipeline Diameter : DN15-DN2000

Accuracy : 0.5% or 0.2%

Flange : GB/ANSI/JIS/BS/Others

Pressure Rate : 0.6MPa-4.0Mpa

IP Class : IP65/IP67/IP68

Contact Now

Electromagnetic Flow Meter for Textile Industry / City Administration / Water Works / Environment Protection


1. Introduction

MLF electromagnetic flow meter, composed of sensor and converter, works based on Faraday’s law of electromagnetic induction law. It is used to measure electrical conductivity of liquid or solid. Generally, the electrical conductivity should be over 5υS/cm(electrical conductivity of tap water, raw water is about 100~500υS/cm),It can also be used to measure various media like acid, alkali, saline solution, paper pulp or pulp and so on. But these media can’t contain a lot of magnetic materials and bubbles.

MLF electromagnetic flow meter is a kind of instrument which is used for measuring the flow conductivity liquid. The meter is widely used in flow measuring of Metallurgy, Chemical Industry, Paper Industry,Environmental Protection, Oil Industry, Textile Industry, Food Industry and City Administration, Water Works,etc.


2. Quick Details

1). It is high resistance, fast response design can make undistorted collection of weak signal and fast response to the flow changes. Its range rate can reach 100:1.

2). It has the function of low conductivity measurement.

3). It has the consistency of converter’s interchange, which can avoid input parameters repeatedly.

4). Wide range of power supply mode is available (DC: 18V-36V/AC: 85V-265V).

5). It is the first domestic company that adopts the function of saving settings before delivery,which can avoid the loss of the parameters.

6). It adopts the international leading excitation technology, which circuit is simple, stable,and reliable.

7). It has the function of infrared remote control and button operation so as to make the operation more convenient.

8). It provides the function of zero correction of sensor and automatic zero adjustment.

9). It has Chinese, English, Korean, Polish, Turkish, French and Portuguese languages for option to satisfy different customers’ requirements.


3. Specification

MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
Accuracy±0.2% or ±0.5%
Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
FlangeGB, ANSI, JIS, BS, Others
PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection ClassIP65, IP66, IP67, IP68
Medium Temperature-25~180
(Please refer to liner material)
-25~80(Please refer to liner material)-25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability≤±0.1% or ±0.25%
Analog Output Error≤±0.02mA
Velocity0.3~10m/s
Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output4-20mA, Pulse, RS485, Hart, Profibus

4. Dimensional Sketches

a. Dimension of Converter

Divided Type



Integrated Type


Battery Powered Type


b. Dimension of Sensor



Pipeline DiameterDimension
LWH
1516095130
20160105137
25160115150
32160135160
40200145175
50200160185
65200180205
80200195215
100250215235
125250245275
150300280300
200350335355
250400400405
300500455460
350500515520
400600575580
450600635630
500600710685
600600835795
700700905910
80080010201030
90090011201120
1000100012451250
1200120014651470

5. Instrument Detection & Maintenance


Electromagnetic flow converter has self-diagnosis function. In addition to the power and hardware circuit fault, The system also give alarm to other faults in general usage. These information are given accordingly prompts in the lower right of the screen.


1. Maintenance and repair


a) Sensor installation site should be consistent with the section four requirements, Please keep the housing clean and tidy;
b)Transmitter should be placed in a clean, ventilated, dry place;
c)Need to inspect every two years, for high precision users, instrument need to be submitted to censorship.


2. Transportation and storage


a)The instrument must be packed before transportation, be carefully handled when loading and unloading.
b)Storage site must be dry, ventilated, avoid corrosive gas erosion, the ambient temperature is not too low or too high;
c)Storage time better not exceed three years.


3,Unpacking and checking


a) The packing can’t be opened with heavy hammer, and should becareful not to damage the instrument
b) Check the content carefully according to the packing list.



Product Tags:

mag flow meter

      

electronic magnetic flow meter

      
Buy cheap Electromagnetic Flow Meter for Textile Industry / City Administration / Water Works / Environment Protection product

Electromagnetic Flow Meter for Textile Industry / City Administration / Water Works / Environment Protection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0