Sign In | Join Free | My ismap.com
China Melan Measurement & Control Instruments (Shanghai) Co.,Ltd. logo
Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
MELAN MEASUREMENT & CONTROL INSTRUMENTS (SHANGHAI) CO., LTD.
Active Member

5 Years

Home > Hydrostatic Level Transmitter >

Corrosion Resistance Hydrostatic Level Transmitter For Tank Measurement

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Corrosion Resistance Hydrostatic Level Transmitter For Tank Measurement

  • 1
  • 2

Model Number : ML2000T

Place of Origin : China

MOQ : 1pc

Price : Negotiation

Payment Terms : T/T

Supply Ability : 10000pcs per month

Delivery Time : 7-10 working days

Packaging Details : In Carton Packing

Product Name : Hydrostatic Level Transmitter

Accuracy : ±0.2% or ±0.1%

Measuring Range : 0~200mH2O

Sensor : Stainless Steel(Cylinder Shape)

Lag : Full Span Better Than 0.01%

Product Types : Common, Oil Resistance, Corrosion Resistance

Contact Now

High Performance Hydrostatic Level Transmitter for Tank Measurement

1. Introduction

ML2000T series static liquid level transmitter adopts imported silicon pressure transducer as sensitive element, utilizing reasonable industry structure to finish stainless steel sealing package. The amplifying circuit can ensure measurement accuracy through laser compensation . The electrical connection cable applies is anti corrosive gas shielded cable which makes the back pressure chamber is directly connected to the atmosphere.

2. Features

  • The tested medium is extensive. As long as the liquid is compatible with the diaphragm material and the paste, it can be measured.
  • The lifetime is long for it has stainless steel material, reasonable sealing package and special cable.
  • It has high accuracy and good stability. The transducer realizes temperature compensation with 0-85℃ and eliminates accuracy influence caused by temperature drift through compensation circuit.
  • ML2000T series is easy installed. Just immerse the probe into medium directly and connect the signal cable to secondary instrument. Adapt to small installation space. When installation, please try to fix the cable to avoid shaking of transducer for shaking can influence the accuracy and lifetime of the transducer.
  • Upgrade features:

① Power supply non polar connection

② Field or Outside lightning prevention design

3. Technical Parameter

Accuracy ±0.2% or ±0.1%
Measuring Range 0~200mH2O
Stability <0.1%FS Per Year
Overload Limit 200%
Power Supply 24VDC or 12VDC
Signal Output Two-wired 4-20mA
Overload Limit 150%~300%
Lag Full Span Better Than 0.01%
Working Temperature 0~85℃
Storage Temperature 85℃

4. Structure & Material

Isolation Diaphragm 316L Stainless Steel
Transducer: Stainless Steel(Cylinder Shape)
Sealing: Fluorine Rubber
Cable: PVC Cable With Shield
Product Types Common, Oil Resistance, Corrosion Resistance

Corrosion Resistance Hydrostatic Level Transmitter For Tank Measurement

5. Configuration

Type Specification Code Illustration
ML2¨¨¨T --------------------------------- Static Liquid Level Transmitter
Transducer 0-------------------------------- Diffused Silicon Transducer
Accuracy 8-------------------------------- ±0.2%
5-------------------------------- ±0.1%
Output 8-------------------------------- 4-20mA
1-------------------------------- 4-20mA, HART, RS485
T--------------------------------
Measuring Mode A-------------------------------- Common Type *
G-------------------------------- Oil Resistance Type(0~200℃)
N-------------------------------- Corrosion Resistance Type
K-------------------------------- Lightning Stroke Resistance Type
Dimension Requirements L-------------------------------- Cable Type (Note 1)
G-------------------------------- Rod Type (Note 2)
Measuring Range 1-------------------------------- 0-1000mmH2O
2-------------------------------- 0-5000mmH2O
3-------------------------------- 0-10000mmH2O
4-------------------------------- 0-20000mmH2O
5-------------------------------- 0-30000mmH2O
6-------------------------------- 0-60000mmH2O
7-------------------------------- 0-100mH2O
8-------------------------------- 0-150mH2O
9-------------------------------- 0-200mmH2O
Display Header D-------------------------------- Multiple Parameters & Modes Digital LED Display Header With HART
L-------------------------------- Common LED Header Without HART
Z-------------------------------- Pointer Header
N-------------------------------- No Header
Electrical Connection 5-------------------------------- M20x1.5 Waterproof Concentrator
Power Supply -A-------------------------------- 24VDC
-B-------------------------------- 12VDC
Additional Type -FL------------------------------ Flange Connection (Note 3)
-NF1---------------------------- Ex-proof Certificate: Exd II CT6
-NS1---------------------------- Intrinsic Safety Type: Exi II CT4
-M------------------------------- Other Requirements (Note 4)
Remarks:
e.g.:ML2088TAL2N5-A-NF1 0-5000mmH2O
Note1: Please indicate cable length behind type if you choose this code
Note2: Please indicate rod length behind type if you choose this code(Max.3m)
Note3: Please indicate flange size behind type if you choose this code
Note4: Please note in order
*: Standard
Order Attention:
1. Indicate the ambient temperature and medium temperature if it is corrosive.
2. Indicate medium density.

6. Installation Method:

(1) Choose a place easy to operate and maintain to install.

(2) Try to be away from the vibration source

(3) Try to be away from the heat source

(4) Better to connect the pipe with the valves

(5) Please clamp on the six-party of the wrench tightly

(6) Please don’t move the connection part between Hirschmann and outer cover.


Product Tags:

hydrostatic type level transmitter

      

static pressure transmitter

      
Buy cheap Corrosion Resistance Hydrostatic Level Transmitter For Tank Measurement product

Corrosion Resistance Hydrostatic Level Transmitter For Tank Measurement Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0